XCQM-5200 Conductivity multi-parameter sensor
$1,501.81
Monitor conductivity, dielectric constant, trace moisture, water activity and temperature simultaneously to detect oil aging.
- SKU
- XCQM-5200
- Minimum order quantity
- 1
- Estimated lead time
- Confirmed after ordering
Product information
Description
XCQM-5200 uses electrochemical impedance spectroscopy (EIS) for online condition monitoring of fire-resistant fluids, hydraulic oils and lubricating oils. It measures conductivity, dielectric constant, trace moisture, water activity and temperature simultaneously.
pS-level conductivity detection identifies quality deterioration trends such as acidification, oxidation and additive depletion. Continuous results support condition-based maintenance, optimized oil-change intervals and reduced reliance on offline analysis.
The sensor monitors both static and flowing oil, with measurements unaffected by flow velocity or viscosity. It suits critical equipment in power generation, petrochemicals, transportation, marine, aviation and motor cooling.
Product highlights
- 1 pS/m conductivity sensitivity
- EIS multi-frequency impedance measurement
- CAN-J1939 / RS485 communication
- IP68, 10 MPa operating pressure
Product dataTechnical Specifications
Measurement
- Compatible media
- Fire-resistant fluids, hydraulic oils, lubricating oils, kerosene, fuels, etc.
- Conductivity range
- 100–200000 pS/m
- Conductivity sensitivity
- 1 pS/m
- Conductivity accuracy
- ±5 pS/m
- Resistivity range
- 6 × 10⁹–6 × 10¹³ Ω·cm
- Dielectric constant range / accuracy
- 1–6 / ±0.01
- Water activity range
- 0–1 aw
- Dissolved water range / accuracy
- 0–10000 ppm / ±10%
Electrical
- Communication protocol
- CAN-J1939 / RS485 Modbus-RTU
- Power supply
- 10–30 VDC
- Power consumption
- 0.4 W
Mechanical
- Mechanical connection
- G1, customizable bypass configuration
- Operating pressure
- 10 MPa
- Ingress protection
- IP68
- Ambient temperature
- -40–85°C
- Oil temperature
- -40–105°C
- Weight
- 100 g